4x4 brass crimp tube

author:MF manufacturerstime:2022-03-16 05:54:42

I know when I chat with domestic electrician friends.,When the main line is branching,Most of the domestic use of puncture clamps。And in Japan is still in useTTerminal crimping wire。

Let's introduce it below.,Japan'sTHow to connect。Do you want to see some of this after contact??What are the advantages and disadvantages between the two??

4x4 brass crimp tube

first,Need to have a12VCharging crimping clamp,Its head can be exchanged freely in the cable shear and crimping clamp。

(4x4 brass crimp tube)4x4 brass crimp tube

(4x4 brass crimp tube)TThe terminal is a kind of crimp terminal。Although it is seen from the shape of the terminal itself.Ctype,But still want to take itTTerminal orTTerminal terminal。

(4x4 brass crimp tube)There are many specifications of the terminal crimp,To be symmetrical,Cannot be mixed。What is mentioned in this article44Number of crimping terminals,Corresponding use44Pressure joint。

Introduction to other crimping terminals in Japan,Introduced in the future article,You can pay attention to the headline of your job.。

4x4 brass crimp tube

(4x4 brass crimp tube)Need to connect the location of the basement of a residential building,Electrical improvement project。The location of the unit door needs to be separated from one ground.。

first,Peeled insulating skin using an electrical knife,The green line in the figure is the Japanese specification22mm²Multi-strand 。

4x4 brass crimp tube

The crimp terminal cannot be pressed to the insulating skin,You can't keep excessive positions in the core wire。Stripping the length of the skin must master。

According to the requirements,WillT44The crimp terminal is topped on two wires,See if it is right。

4x4 brass crimp tube

After confirming that the model of the press is correct, press the switch to press the switch.。

4x4 brass crimp tube

Change the angle before crushing,The position of the opening must let it be in the middle of the two lines,Do not shift before pressing the switch。

4x4 brass crimp tube

The crimping clamp is completed after the crimp,It will automatically stop crimping。Don't worry, always press,Excessive strength causes damage。

No matter how you look from the sound or your hand,It can be easily judged that it has been pressed.。

4x4 brass crimp tube

Press one terminal,Probably need2-3Seconds or so。Look carefully, there are two recessed strips above the terminal.,The crimp is just pressed in that position.。

4x4 brass crimp tube

After the opening of the terminal is crimped,Basically, I can't see the gap.

4x4 brass crimp tube

Surface smooth and smooth,Very firm, connect two lines together。

(4x4 brass crimp tube)4x4 brass crimp tube

There is no wall on the side of the corridor on the first floor.,Although it will not be rained directly,But also belongs to the wet zone。

If it is not a ground wire,It also needs on the basis of insulating tape,Wrap the waterproof tape。

4x4 brass crimp tube

Normal is more insulating tape with gray,Green insulating tape is limited to ground wire。

(4x4 brass crimp tube)4x4 brass crimp tube

Wrap the tape,Complete the cable tied up on the cable hook。After the electrical standard standard is used,The crimp is still very strong。

4x4 brass crimp tube

Yellow hook is our hanging this time。The angle iron above the hook is installed more than 20 years ago.,It feels firm and it is useful.。Hook is stainless steel。

4x4 brass crimp tube

It is used today.T44Number terminal crimped once,But some models need to be crimped twice or three times.。

The Japanese wire connection is basically crimped.,The future article will introduce the methods and types of Japanese wire connections.。Welcome to subscribe“Occupancy”Headline。Point my avatar can also check Other dry goods about Japanese electrical!

You feel JapanTConnection terminal?Compared with domestic commonly used puncture piercles,Which method is good??