13306647218

Copper Tube Information

Company dynamics

brass boiler tube brush

author:MF manufacturerstime:2022-03-15 03:02:48

(brass boiler tube brush)

Cleaning oil boiler cleaning agent is used to clean each industry(oil、Chemical industry、Textile、printing and dyeing、Chemical fiber、plastic、Building materials、Heating)Widely used thermal oil furnace,Or heat exchange equipment for working medium with thermal oil。

Scope of application:

1、Heavy oil intens and oil in cleaning heat transfer oil systems、Shell。

(brass boiler tube brush)2、Cleaning of stubborn heavy oil in the surface of the mechanical equipment。

Product Features:

1、Quickly remove the internal pipes and heat exchanger on the internal pipe and heat exchanger。

2、Neutral non-toxic and corrosion process,Tone the internal pipe and heat transfer surface of the thermal insulator and heat exchanger。

3、Dissolve oil、Optical faster,completely dissolved,No residue。

4、Simple and convenient use,No professional operation,Follow the instructions for use。

(brass boiler tube brush)5、Completely environmentally friendly,Product tasteless、Non-toxic、Nonflammable、No corrosion is cleaned,Stimulating,Do not damage the skin,Can be discharged directly after cleaning。

Cleaning process:Emissions Old Oil→Pre-wash→Cleaning→Wash①→Wash②→Wash③→Add new oil→Dehydration→normal operation

Operating method:

(1)Emissions Old Oil:Heating system,Heat the heat transfer oil to70-80℃,Take advantage of all thermal oil in the heat emission system,According to conditions,Make the residual oil in the system to release,Can't put the joined cleaning agent through penetration、Strip、Dissolve action makes oil,Extrovert system。

(2)Pre-wash:Wash the special agent according to the total amount of circulating water1.5%After metering,Input system in any part of the heating system,Full of water to the system,Turn on the circular pump for loop,Using the heating furnace to rise to60℃±5℃,Related valves of each reactor in the switching system,Enable all parts in the system to get cycles。Three to five hours,Open all low sewage valves of the system,Water in the emission system。

(3)Cleaning:Wash the special agent according to the total amount of circulating water4.5~6.5%After metering,Input system in any part of the heating system,And after the system is filled with water,Turn on the circular pump for loop,Heat cleaning agent with heating furnace90℃±5℃。Switching system valve,Clean all parts in the system,Valve switching is performed at an hour。The whole cleaning time is not less than24Hour。

(brass boiler tube brush)(4)Wash①:Add water to the system,Turn on the circular pump for loop,Using the heating furnace to rise to90℃±5℃,Switching system related valves,Enable all parts in the system to get cycles。Rinning the system,Three hours,Open all low sewage valves of the system,Water in the emission system。

(5)Wash②:Further, add water to the system,And open the circular pump for loop,Using the heating furnace to rise to90℃±5℃,Switching system related valves,Enable all parts in the system to get cycles。Rinning the system,Three hours,Open all low sewage valves of the system,Water in the emission system。

(6)Wash③:Add water to the system,Turn on the circular pump for loop,Using the heating furnace to rise to90℃±5℃,Rinning the system,Three hours,Open all low sewage valves of the system,Water in the emission system。Drainage,According to conditions,Water is removed from the compressed air purge system。

(7)Add new oil:Inject new thermal oil into the system。

(8)Dehydration:Its dehydration method is equivalent to the dehydration standard before the use of the new system。

(9)normal operation:The system is working properly。